Skip to main content
This page covers a single, non-clustered appliance. If you run two or more clustered appliances, use the Cluster in-place upgrade instead — that path has zero downtime. A standalone upgrade involves a brief reboot (a few minutes) while the appliance restarts into the new version.
New to how this works? Read System upgrade first — it explains the signed bundle, the A/B slots, and the automatic safety net.

Before you start

Go to https://<your-appliance-address> and sign in with the owner account. Software updates are owner-only.
Obtain enclave-update-<version>.tar.gz from your Kvelden account team and keep it on the computer you’re using. No internet access is needed on the appliance.
The appliance reboots once to activate the new version, so users are briefly offline (typically a few minutes). Schedule accordingly and let users know.

Upgrade steps

1

Open Software Update

In the admin area, go to System → Software Update. You’ll see an Upload a bundle panel and an Update history list of previous upgrades.
2

Upload the bundle

Select Choose bundle… and pick your enclave-update-<version>.tar.gz file. The upload progress is shown. The appliance accepts only a properly named, Kvelden-signed bundle.
3

Review the preflight report

The appliance automatically verifies and preflights the bundle:
  • Signature and format are valid.
  • The target version is newer than what’s installed (downgrades are refused).
  • There is enough free disk space to apply.
Confirm the report shows the expected from → to versions and that all checks pass. If preflight fails, see Troubleshooting — nothing has been changed on the appliance yet.
4

Apply the update

Select Apply update and confirm your password when prompted (step-up authentication). This starts the upgrade — from here it runs on its own.
5

Watch the live progress

A progress stepper shows each stage and follows the upgrade through the reboot:
  1. Upload bundle — staged on the appliance.
  2. Verify & preflight checks — signature + version + capacity.
  3. Install to standby slot — the new OS is written to the inactive A/B slot.
  4. Reboot & activate — the appliance restarts into the new slot and applies the new application.
  5. Complete — the new version is health-checked and committed.
The appliance is briefly unreachable during Reboot & activate. The stepper persists across the reboot — if you refresh or reopen the page, it resumes reporting where the upgrade actually is, and ends with an explicit “completed” (or a rolled-back “failed”).
6

Verify the new version

When the stepper reports completed, sign in again and confirm:
  • The version shown under System matches the new release.
  • Your data is intact — open a room / file you know.
  • System → Diagnostics is green.

If something goes wrong

The upgrade is self-healing. After the reboot the appliance health-checks the new version:
  • Healthy → the new version is committed and the previous slot is kept as the fallback for the next upgrade.
  • Unhealthy → the appliance automatically rolls back to the previous slot and restores the pre-update database snapshot. It comes back on the old version with your data intact, and the stepper reports failed with the reason.
You do not need to do anything to trigger rollback — it is automatic and the OS and application always move together (never a split state).

Troubleshooting

The bundle’s signature or format didn’t validate, or it isn’t newer than the installed version. Re-download the bundle from Kvelden and confirm it’s the correct release. Nothing was changed on the appliance.
Free some space and re-run preflight. The most common cause is old uploaded bundles: remove previous bundles listed under Software Update, then try again.
A brief unreachable window during Reboot & activate is normal. Leave the page open — it resumes automatically when the appliance is back. If it hasn’t returned after several minutes, refresh the page; the stepper re-attaches to the live status.
That’s the automatic rollback: the new version failed its health gate, so the appliance reverted safely. Review the failure reason in the stepper / Update history, capture a support bundle (System → Diagnostics), and contact Kvelden support before retrying.

Review past upgrades

Every upgrade (and rollback) is recorded under System → Software Update → Update history with the from/to versions, timestamp, and outcome.