This page covers a single, non-clustered appliance. If you run two or
more clustered appliances, use the
Cluster in-place upgrade instead —
that path has zero downtime. A standalone upgrade involves a brief
reboot (a few minutes) while the appliance restarts into the new version.
New to how this works? Read System upgrade
first — it explains the signed bundle, the A/B slots, and the automatic
safety net.
Before you start
Sign in as the owner
Sign in as the owner
Go to
https://<your-appliance-address> and sign in with the owner
account. Software updates are owner-only.Have the signed bundle ready
Have the signed bundle ready
Obtain
enclave-update-<version>.tar.gz from your Kvelden account team and
keep it on the computer you’re using. No internet access is needed on the
appliance.Plan a short maintenance window
Plan a short maintenance window
The appliance reboots once to activate the new version, so users are
briefly offline (typically a few minutes). Schedule accordingly and let
users know.
Take a backup (recommended)
Take a backup (recommended)
The upgrade takes an automatic safety snapshot, but a fresh verified backup
(Admin → Backup & Restore) beforehand is best practice.
Upgrade steps
1
Open Software Update
In the admin area, go to System → Software Update. You’ll see an
Upload a bundle panel and an Update history list of previous
upgrades.
2
Upload the bundle
Select Choose bundle… and pick your
enclave-update-<version>.tar.gz
file. The upload progress is shown. The appliance accepts only a properly
named, Kvelden-signed bundle.3
Review the preflight report
The appliance automatically verifies and preflights the bundle:
- Signature and format are valid.
- The target version is newer than what’s installed (downgrades are refused).
- There is enough free disk space to apply.
4
Apply the update
Select Apply update and confirm your password when prompted (step-up
authentication). This starts the upgrade — from here it runs on its own.
5
Watch the live progress
A progress stepper shows each stage and follows the upgrade through the
reboot:
- Upload bundle — staged on the appliance.
- Verify & preflight checks — signature + version + capacity.
- Install to standby slot — the new OS is written to the inactive A/B slot.
- Reboot & activate — the appliance restarts into the new slot and applies the new application.
- Complete — the new version is health-checked and committed.
6
Verify the new version
When the stepper reports completed, sign in again and confirm:
- The version shown under System matches the new release.
- Your data is intact — open a room / file you know.
- System → Diagnostics is green.
If something goes wrong
The upgrade is self-healing. After the reboot the appliance health-checks the new version:- Healthy → the new version is committed and the previous slot is kept as the fallback for the next upgrade.
- Unhealthy → the appliance automatically rolls back to the previous slot and restores the pre-update database snapshot. It comes back on the old version with your data intact, and the stepper reports failed with the reason.
Troubleshooting
Preflight failed — bundle rejected
Preflight failed — bundle rejected
The bundle’s signature or format didn’t validate, or it isn’t newer than the
installed version. Re-download the bundle from Kvelden and confirm it’s the
correct release. Nothing was changed on the appliance.
Preflight failed — insufficient disk space
Preflight failed — insufficient disk space
Free some space and re-run preflight. The most common cause is old uploaded
bundles: remove previous bundles listed under Software Update, then try
again.
The page looks stuck during the reboot
The page looks stuck during the reboot
A brief unreachable window during Reboot & activate is normal. Leave
the page open — it resumes automatically when the appliance is back. If it
hasn’t returned after several minutes, refresh the page; the stepper
re-attaches to the live status.
It came back on the old version
It came back on the old version
That’s the automatic rollback: the new version failed its health gate, so the
appliance reverted safely. Review the failure reason in the stepper /
Update history, capture a support bundle (System → Diagnostics),
and contact Kvelden support before retrying.
Review past upgrades
Every upgrade (and rollback) is recorded under System → Software Update →
Update history with the from/to versions, timestamp, and outcome.